Civil QC Inspector Responsibility & For Adnoc standard and specifications I am Civil QC Inspector for Adnoc.I'll Knowledge you about as a civil QC Inspector Responsibility.

Reinforcement (Rebar)..
04/03/2026

Reinforcement (Rebar)..

08/02/2026

Types of Steel are used
8mm,10mm,12mm,16mm,20mm,25mm,30mm,32mm
Steel Length - 12m
SteelGrade- 500mpa
Steel lapping length -50d
Two types of steel test:-
1.Mechanical test
2.Chemical test
a)Tensile strength
Tensile strength is the maximum stress steel can withstand before breaking.
Bend-135°C
Rebend- 180°C
On each 500 tons of each Dia of reinforcement bar
b) Chemical test
1. Carbon
2. Phosphorus
3. Sulphur

07/02/2026

Q.How many types of concrete are used?
Ans.
1.Mass concrete C40/20(TEMPERATURE - 26°C. SLUMP- 175±25%(150-200mm)
30%OPC & 70%GGBS
2.Normal concrete C40/20(TEMPERATURE - 32°C. SLUMP- 175±25%(150-200mm)
45%OPC & 55%GGBS
3.Blinding concrete C20/20(TEMPERATURE - 32°C. SLUMP- 125±25%(100-150mm)100%OPC
4.Screed concrete C20/10(TEMPERATURE - 32°C.SLUM- 125±25%(100-150mm)100% OPC

Full form :-
C40- (C) Means - compressive strength
20 is Aggregate size
OPC - Ordinary Portland Cement
GGBS - Ground Granulated Blast Furnace Slag

Adnoc Standard Slump- ASTMC143
07/02/2026

Adnoc Standard Slump- ASTMC143

04/02/2026

Soil test :-
1. Natural water content
2. Modified proctor compaction
3. liquid limit
4. Uniformity Coefficient
5. Particle size disturbution
6. Sulphate
7. Plasticity index
8. Chloride

16/01/2026

Adnoc Specifications.(Important Remember it For Civil QC)

AGES-SP-01-001(Concrete Supply & construction Specifications)

AGES-SP-01-003(Structural Design Basis Specifications)

AGES-SP-01-004(Anchor Bolt & Grouting Specifications)

AGES-SP-06-006(Site Preparation, Earthworks and Bund Construction Specifications)

AGES-SP-01-009(Onsite Material Sampling & Testing Specifications)
AGES-SP-07-001(Cathodic Protection Specifications).